Incorrect mapping could have disastrous results. Map the Real I/O for PLC-5 to ControlLogix Conversionįinally, map the I/O bits to the real ControlLogix I/O Tags.
#CONVERT RSLOGIX 500 TO RSLOGIX 5000 HOW TO#
If you are unsure how to do this, read up on how to add Local I/O and Remote I/O. In this case, we just have an input module in slot 5, and an output module in slot 6. Add I/O ModulesĪt the bottom of the I/O tree, add your I/O Modules to the I/O Configuration tree. Open your ladder, and you will see that the project is translated. this is an L5K project, so Studio 5000 will ask to import this file. Now that your project is created, open the project in RSLogix / Studio 5000.
Open your new project in RSLogix / Studio 5000 You can also think of them as “Shortcuts” to another tag.įourthly, allow the project to translate, then launch RSLogix / Studio 5000. Remember that Aliases are just another name for a tag. The Aliases will allow us to point the old tag names to the new I/O Locations once our project is complete. Click “Next”.Īt this point, we’ll specify what aliases to create. You will also specify the type of ControlLogix processor, and the revision. In addition, we’ll do a complete save, and export all applicable files.Ĭlose RSLogix 5, then browse for the. Be sure to save your project as a “.PC5” file. Open your PLC-5 project in RSLogix 5, then click “File | Save As”. Likewise, if you are converting an SLC project, be sure to click on the image of the SLC. In Studio / RSLogix 5000, assuming the utility is installed, click on “Tools | Translate PLC-5/SLC” Export the PLC-5 ProjectĬlick on the image of the PLC-5 to Launch RSLogix 5. Launch the PLC-5 to ControlLogix Conversion Utility We will convert this to ControlLogix using Rockwell’s conversion utility. In short, this is a very simple PLC-5 project. When the timer is finished, the output will energize. In this case, we have a switch that starts a timer. FactoryTalk View SE Trends and Data LogĬonsider the following project.Beginning a FactoryTalk View SE Project 500 project file, you can use the using the embedded conversion utilities to import your code into RSLogix 5000 or Studio 5000.Derivative Settings for ControlLogix PID Enhanced.Integral Settings for ControlLogix PID Enhanced.
Proportional Settings for ControlLogix PID Enhanced (PIDE).2.0 that is included with version 19 and later of the RSLogix 5000.
#CONVERT RSLOGIX 500 TO RSLOGIX 5000 MANUAL#
Proportional, Integral, Derivative (PID) Reference Manual Converting PLC-5 or SLC 500 Logic to Logix-Based Logic Catalog.